Shanghai Newreal Auto-System Co., Ltd.
Main products:Flame Treatment System,Plasma Treatment System,Linear Burner,Solenoid Valve,Pressure Gauge
Products
Contact Us
  • Contact Person : Ms. LIU Lisa
  • Company Name : Shanghai Newreal Auto-System Co., Ltd.
  • Tel : 86-21-55228732,13817660627
  • Fax : 86-21-55228731
  • Address : Shanghai,shanghai,Zone C-1, No.165 Xiangyin Rd, Yangpu District,
  • Country/Region : China

Flame treatment system

Flame treatment system
Product Detailed
Flame treatment system

Flame Treating Burner

 

Type                                         A530-8” Smooth Flame

Output (Max)                                                             30,300Kcal/hr, 120,000BTU/hr, 35-16Kw/hr

 

Gas

SupplyPressure                                                         1 bar, +0.1 bar

 

Type of Gas                                                               Natural

 

GasCV                                                                    TBA

 

Gas Consumption (Maximum)                                      3.3Nm3/h NormalInlet Pressure                                                                   1 Bar Maximum Inlet Pressure                                                                   2 Bar

Air

Air Pressure minimum                                                 6 bar at point of use

 

Pressure Fluctuation                                                   +0.3 bar

 

DrewPoint                                                                0°C

 

Quality                                                                      Free of Oil, water & contamination

 

Combustion Air Pressure                                               0.5 - 2 Bar

 

Air Consumption – Maximum                                       36.3 Nm3/hr

 

Electrical Supply

 

Electrical Supply                                                        230V 1 Ph 50 Hz

Control Voltage for Actors and Sensors                        24V DC, 24V AC

Electrical Regulations / Wiring                                     EN

Control Valves                                                           230V AC, 50Hz

 

Maximum Power Consumption                                     1 KW

 

Integral components

 

Flame Failure Devices                                                Kromschroder IFD258-5/1W

 

System Purge Time                                                    30 seconds

 

Unimixer Type                                                           6 FUM Jet Size        No 7

PLC Type PLC                                                           Siemens S7 216 CPU Flat Screen Display Type                                                                        Siemens OP17

System Colour                                                           Ral 7035 Grey

Flame treatment system



Copyright Notice @ 2008-2022 ECVERY Limited and/or its subsidiaries and licensors. All rights reserved.